Troubleshooting procedures, Warning – Maytag MLE/MLG23MNA User Manual

Page 13

Advertising
background image

©2004 Maytag Appliances Company

16022904 Rev. 0

13

Troubleshooting Procedures

!

WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.

General Specifications

Wattage Specifications

Exhaust Ducts

Capacity

6.0 Cubic Feet

One washer load is a full dryer load

Motor

Thermo-protected against overload auto-reset

1/4 HP, 120 Volt, 60 Hz

Air Flow

Cubic feet per minute exhausted from dryer

220 CFM

Tumbler

Revolution per minute

52 RPM

Rotation

Drum Turning, when viewed from the front

Clockwise

Heat Source

• Electric

• 240 volt, 5600 watts, 30 amp fuse

• Gas

• Single port burner 24,000 BTU/hr.

direct ignition, automatic shut-off

Exhaust

Venting size

4"(10.2 cm) duct, rigid aluminum

duct work. (See installation instruc-

tions that are provided with the

product for additional information.)

Makeup Air

Free opening

Requires 30 sq. in. per dryer pocket

Static Pressure

Single unit exhausting, 4" round rigid

Should not exceed 0.92" or less

than 0 water column inches

DESCRIPTION

WATTS

Gas Dryer

350 Maximum without igniter

Electric

5900 (240V)/5600 208V)

Heating Element

5600 (240V)/5100 (208V)

Igniter

(NOTE: Ohm room temperature 180-400)

600