Troubleshooting Procedures

!

WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.

Single Dryer Troubleshooting Guide

Control

Does Not

Respond To

Program

Key Inputs

Enter service mode.

Does display contain

a diagnostic code?

Exit service mode.

Does the display

show "Select

Cycle"?

Does the keys work

in service mode?

Unplug dyer and check

membrane switch tail

connection to the board.

Plug the dryer back in..

See diagnostic code

troubleshooting guide

Unplug dryers and check

wiring and termination

between door switch and

control board.

If problem persists replace

membrane switch.

If problem

persists, replace

control board.

If problem persists,

replace control board.

Yes

No

No

Is the door shut?

Close the door.

Yes

Yes

No

Put the proper

number of coins

into the coin drop.

No

Does the help mode

show that the door is

shut?

Unplug the dryer , then

plug it back in.

If problem

persists, replace

control board.

Yes

Yes

Unplug dryer and check

continuity of the door

switch when the door is

opened and closed.

Does door switch

open and close

properly?

Adjust door switch

or replace it if

necessary.

No

No

Yes

Advertising