Troubleshooting procedures, Warning, Stack dryer troubleshooting guide – Maytag MLE/MLG23MNA User Manual

Page 29

Advertising
background image

©2004 Maytag Appliances Company

16022904 Rev. 0

29

Troubleshooting Procedures

!

WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.

Stack Dryer Troubleshooting Guide

Display Is

Blank

Make sure both

dryers are plugged

into live power

source.

Enter operator

mode using

service switch. Is

diagnostic code

displayed?

See Diagnostic

code Trouble

Shooting Guide.

Unplug dryers. Check wiring

and terminations between

transformer, service switch

and control board.

Plug in dryer.

Does 115VAC

appear across the

primary of the

transformer?

Check wiring to

transformer, power

at outlet and

breaker.

Initiate reset

sequence. If

problem persists

replace control

board.

Does each of 6.7 VAC,

22.6 VAC and 20.7 VAC

appear across

transformer secondary?

Replace the transformer.

Inspect control board for
burned components and

replace it if damaged.

Yes

No

No

Yes

Yes

No

Abnormal

Display Or

Function

Cycle power to

both dryers.

Initiate a service

cycle.

If problem

persists, initiate

reset sequence.

If problem persist,

replace control

board.

Upper or

Lower Dryer

Has Zero

Minutes

Remaining

In Display.

Open

corresponding

dryer door. Did

display change?

Unplug both dryers and

open doors. Check

continuity of problem

door switch and replace

it if shorted.

The dryer door must

be opened after the

end of a cycle. This

is a safety check on

the door switch.

Does door switch

open and close

properly?

Check wiring and

termination

between door

switch and control

board.

Replace door

switch.

If problem persist,

replace control board.

No

Yes

Yes

No