Warning, Disassembly procedures – Maytag MLE/MLG23MNA User Manual

Page 49

Advertising
background image

©2004 Maytag Appliances Company

16022904 Rev. 0

49

WARNING

!

To avoid risk of electrical shock, personal injury or death;
disconnect power to unit before servicing.

Disassembly Procedures

Gas Valve

1. Disconnect power supply to unit
2. Remove Front Panel.
3. Shut off gas supply and disconnect supply line to

valve.

4. Disconnect wire harness at valve coils.
5. Disconnect wires from radiant sensor.
6. Loosen brass nut attaching angle connector to gas

valve.

7. Remove two screws holding valve and burner

assembly to base.

8. Slide valve bracket out of slot in base and remove valve

and burner assembly.

9. Remove two screws holding gas valve to bracket on

underside.

Combustion Cone

1. Disconnect power supply to unit.
2. Remove Front Panel.
3. Remove burner and igniter. Be careful igniter is fragile.
4. Remove wires from hi-limit thermostat.
5. Remove screw in front of cone holding it to base.
6. Remove screw at back of combustion cone holding

cone tab to inlet duct.

7. Pull combustion cone out of dryer.

Inlet Duct

1. Disconnect power supply to unit.
2. Remove Front Panel.
3. Remove Front Shroud Assembly, belt and tumbler.
4. Remove screws securing heat cone to base and to

inlet duct.

Inlet Duct

Retaining

Clip

Radiant

Sensor

Hi-Limit

Thermostat

Combustion

Cone

5. Remove tumbler back assembly.

Note:

Four screws are accessible from behind dryer.

5. Remove three screws securing inlet duct to the

tumbler back assembly. The two lower screws are
under the felt seal of the tumbler back assembly.

Note:

For proper inlet duct to tumbler back assembly

alignment when reinstalling, align inlet duct to
large hole in the tumbler back assembly and
fasten top screw first.

Note:

Terminal insulators are used on each end of the

element which attaches to spade connectors.
These spade connectors are "crimped" to the
wire and held in the insulator by small barbs on
each side of the terminal. The barb must be bent
parallel with each terminal before element
package can be removed from the enclosure.
Three screws hold the element package to the
enclosure.

Terminal
Insulator

Hi-Limit

Thermostat

Heater Enclosure

Thermal Fuse

Heater Enclosure

1. Disconnect power supply to unit.
2. Remove Front Panel and Door.
3. Remove screw holding Heater Enclosure shield to

base. Remove Heater Shield from dryer.

4. Remove screw in back of enclosure holding tab to inlet

duct.

5. Remove wires from the Thermal Fuse and heater

terminal on left side of enclosure. Remove purple wire
from Hi-Limit Thermostat.

6. Pull heater assembly out of dryer.