Troubleshooting procedures, Warning, Stack dryer diagnostic code – Maytag MLE/MLG23MNA User Manual

Page 35

Advertising
background image

©2004 Maytag Appliances Company

16022904 Rev. 0

35

Troubleshooting Procedures

!

WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.

Stack Dryer Diagnostic Code

d1 or d17

Door Sense Problem

Try to Clear the

diagnostic code by

pressing the

Delicates keypad

for more than 1

second while the

code is displayed.

d1 indicates the

upper dryer door,
d17 indicates the

lower dryer door

on control board or

due to power line

interference

Did the

diagnostic code

clear?

False

indication.

Control board

is operating

normally.

Replace the

control board.

If diagnostic code

still appears, the

power line is noisy

and should be

tested.

No

Yes

d4 or d20

Motor Control Circuit

Problem

Push the Perm

Press program

keypad to start the

diagnostic

program.

Try to Clear the

diagnostic code by

pressing the

Delicates keypad

for more than 1

second while the

code is displayed.

Did the

diagnostic code

reappear?

False

indication.

Control board

is operating

normally.

Check the wiring between the

control board and the motor.

Fix the power line

disturbance.

Is the power

line supply to the

machine noisy?

Replace the

control board.

No

No

Yes

d5 Blocked Coin 1

(d13 Blocked Coin 2)

Or Coin Drop Circuit

Problem

Unplug dryer and

check the wiring

and termination

between the coin

drop and the

control board.

Check for an

object blocking the

coin drop optic

sensor. It takes 8

seconds for the

control to

recognize the

blockage.

If the problem still

exists, replace the

coin drop coin

sensor.

If the

problem

still exist,

replace the

control

board.

Yes

Advertising