Troubleshooting procedures, Warning, Single dryer troubleshooting guide – Maytag MLE/MLG23MNA User Manual

Page 20

Advertising
background image

20

16022904 Rev. 0

©2004 Maytag Appliances Company

Troubleshooting Procedures

!

WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.

Single Dryer Troubleshooting Guide

Display

Flashes In

User Mode

Check wiring and

termination between

vault switch and

control board.

Unplug dryer. Disconnect lower

connector from control board.

check for continuity between

terminals 7 and 8 of connector

while cycling vault switch.

Reconnect AA1. If

problem persists,

replace control

board

Does vault switch

open and close

properly?

Replace vault

switch.

Make sure that the

vault box is in all the

way. If it is out, the

display will flash.

Check for the proper

adjustment of vault

switch.

Display

shows "Add"

Or "Available"
When Not In A

Cycle And No

Coins Have

Been Added

If price suppression

is not desired.

Deselect it in service

mode.

Go to the section "Abnormal

Display Or Function"

Is price suppression

mode selected?

Normal operation. Price

suppression is typically used when

a different control system that has

its own display is responsible for

starting the machine.

Yes

No

Coins

Dropped Into
Machine And

Credited Are

Eventually

Lost

If clear escrow mode

is not desired,

deselect it in service

mode.

Go to the section "Abnormal

Display Or Function"

Is the clear escrow

mode selected?

Normal operation. Money in escrow

is cleared out after 30 minutes

pass with no cycle in process or

coin related activity.

Yes

No

No

Yes