Troubleshooting Procedures

!

WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.

Single Dryer Diagnostic Program

Dryer

Diagnostic

Program

The dryer must be at or near

room temperature and plugged

in with the door closed to run

this program. No user program

should be in progress

Enter operator mode

using the service

switch

Push the delicates

program keypad

for more than 1

second

See the single dryer

diagnostic code guide

Is there a

diagnostic

code?

Are all of the

segments in the

display working?

Replace the control

board

See the single dryer

diagnostic code guide

Push the permanent

press program keypad

to start the diagnostic

program

Is there diagnostic

code?

Is the heater on (Allow
ample time for the gas

flame to ignite)?

See "Dryer Drum Will Not

Turn" in the troubleshooting

guide

Is the dryer drum turning?

See "Dryer Will Not

Heat" in the

troubleshooting guide

To cancel the diagnostic

program, push the delicates

program keypad

Dryer is operating

normally

Exit operator mode using

the service switch

No

Yes

No

Yes

Yes

No

No

Yes

No

Yes

Advertising