Troubleshooting procedures, Warning, Stack dryer diagnostic code – Maytag MLE/MLG23MNA User Manual

Page 36

Advertising
background image

36

16022904 Rev. 0

©2004 Maytag Appliances Company

Troubleshooting Procedures

!

WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.

Stack Dryer Diagnostic Code

d12 or d14 Motor

Sensed Problem

d12 indicates

lower dryer motor

sense. d14

indicates upper

dryer motor sense

Clear diagnostic

code by pushing a

Delicates keypad

for at least 1

second while code

is displayed.

Does

diagnostic code

remain?

False indication

control board

Replace control

board

No

Yes

d9

Voltage Problem

Less Than 90 VAC

Try to clear the

diagnostic code by

pressing the

Delicates keypad

for more than 1

second while the

code is displayed.

Exit service mode , and pause for

10 seconds, enter service mode.

Did the

diagnostic code

cancel?

Low voltage was

sensed on the

power line, but is

now ok.

Yes

No

Install reader or use PDA to change mode out of

Gen 2 debit mode

Check wiring

between debit

card reader

and control

board

Is card reader

installed?

Power down and

up machine to

reset card reader

Replace card

reader or

control board.

No

d16

PR Models Only

Check installation

to insure proper

power going to this

dryer. If d9

persist, check the

wiring or replace

the transformer

Are other machines

at this location giving a d9

diagnostic code?

Check installation

to insure proper

power going to all

of the dryers

If problem persists replace

the control board.

Yes

No

Advertising