Troubleshooting procedures, Warning, Stack dryer troubleshooting guide – Maytag MLE/MLG23MNA User Manual

Page 33

Advertising
background image

©2004 Maytag Appliances Company

16022904 Rev. 0

33

Troubleshooting Procedures

!

WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.

Stack Dryer Troubleshooting Guide

Operator

Options

Revert To

Defaults

Setup operator

options as desired

unplug machine for

minimum 15

seconds, then plug in.

If problem

persists, replace

control board

Display

Flashes In

User Mode

Check wiring and

termination

between vault

switch and control

board.

Unplug dryer. Disconnect lower

connector from control board.

check for conuity between

terminals 7 and 8 of connector

while cycling vault switch

If problem

persists, replace

control board

Does vault switch

open and close

properly?

Replace vault

switch.

No

Yes

Dryer

Runs

Without

Program

Selection

Check for welded

motor relay and

replace if necessary.

If problem

persists, initiates a

dryer service

cycle.

Dryer
Drum

Will Not

Turn

Check wiring and termination

between control board, motor

relay, door switch, and motor.

Does dryer door

switch open and

close properly?

Replace Door

switch.

Close the dryer door and enter

operator mode using service

switch. Push a delicates keypad

for at least 1 second

Did a diagnostic code

appear?

See the PD

stacked dryer

diagnostic code

troubleshooting

guide.

If problem

persists, replace

control board.

Does 25 VDC appear

across coil of motor

relay?

Replace motor

relay.

No

No

Yes

Yes

Yes

No