Warning, Disassembly procedures – Maytag MLE/MLG23MNA User Manual

Page 41

Advertising
background image

©2004 Maytag Appliances Company

16022904 Rev. 0

41

WARNING

!

To avoid risk of electrical shock, personal injury or death;
disconnect power to unit before servicing.

Disassembly Procedures

Front Shroud Assembly Removal

1. Disconnect power supply to unit.
2. Remove Front Panel and Door Assembly.
3. Remove hold down brackets securing Top Cover to the

Cabinet.

4. Remove four outer perimeter screws holding Shroud

Assembly to cabinet.

NOTE: Remove the lowest outside screws on each

corner and then the top outside screws. Leave
the four inner screws in place.

Remove these
four screws.

Screws

5. Pull Front shroud Assembly out and away from

tumbler.

Note:

Partially lift the Top Cover.

Note:

When reinstalling the Front Shroud Assembly,

lift the front inner edge of the tumbler to allow the
front of the tumbler to rest on the teflon (Rulon™)
bearings on the shroud and tumbler front
assembly. Also, check the front felt seal to
ensure it is outside the lip of the tumbler.

Outlet Duct, Shroud & Tumbler Front

1. Disconnect power supply to unit.
2. Remove the shroud and tumbler front assembly from

the dryer.

3. Remove the two screws securing the shroud to the

tumbler front and the two screws securing the shroud
to the outlet duct. Pull the shroud free from the
assembly.

4. When reattaching the outlet duct assembly to the

tumbler front, install the center screw (found above the
grid area) first, followed by the four outside screws in
any order.

4. Remove the four 1/4" hex head screws and the one

cross recess countersunk screw securing the outlet
duct to the tumbler front.

Note:

Two of the hex head screws are hidden under the

felt seal. Pull the outlet duct free from the
tumbler front.

Install First

Screws

Remove
Four
Screws

Remove
Five Screws

Advertising