MITSUBISHI ELECTRIC FX2N User Manual

Page 35

Advertising
background image

FX2N-32DP-IF Profibus-DP Interface Unit

Advanced Devices 4

4-9

4.2.3

Configuration Status (M8040 ~ M8059 and D8040 ~ D8059)

M8040 ~ M8059 are reserved. The configuration bytes in D8040 ~ D8059 define the amount of
data which is exchanged between the corresponding I/O units/blocks, special function blocks
and the DP-master.

*1 This value shows as following Figure.

Ex.1 10 hex = 1 byte (8 bit) inputs not consistent
Ex.2 63 hex = 4 word outputs not consistent

Figure 4.4: Configuration Data

Table 4.10:Special Data Registers (D8040 ~ D8059)

Diagnostic Device

Name

Description

D8040 (



)

Lower 8 bits Configuration data 1

*1

The data registers D8040~D8055 display the
actual configuration of the node station. After
power on, when the 32DP-IF is in the search
baud rate state or in the wait configuration
state, these data registers contain the default
configuration data.

Higher 8bits Configuration data 2

*1

D8041 (



)

Lower 8 bits Configuration data 3

*1

Higher 8bits Configuration data 4

*1

D8042 (



)

Lower 8 bits Configuration data 5

*1

Higher 8bits Configuration data 6

*1

:
:

:
:

D8055 (



)

Lower 8 bits Configuration data 31

*1

Higher 8bits Configuration data 32

*1

D8056 ~ D8059

Reserved

Length of data
00 = 1 byte/word
:
:
15 = 16 byte/word

Input/output
00 = Special format
01 = Input
10 = Output
11 = Input and output

Byte/Word
0 = Byte
1 = Word

Consistency
0 = Consistency of byte/word
1 = Consistency of entir length

bit 0

bit 7

Advertising