Light path diagnostics leds, Light, Path – IBM BladeCenter T Type 8720 User Manual

Page 108: Diagnostics, Leds

Advertising
background image

Table

6.

Troubleshooting

charts

(continued)

Device

Suggested

action

Updating

the

switch-module

configuration

through

the

switch

does

not

save

the

management-module

NVRAM.

If

you

log

in

to

the

Ethernet

switch

module

directly

(through

the

Ethernet

switch-module

Web

interface

or

Telnet

interface

instead

of

through

the

management

module

Web

interface)

and

update

the

switch

module

configuration,

saving

the

new

configuration

saves

only

to

the

switch

NVRAM,

not

to

the

management-module

NVRAM.

The

management

module

will

not

be

able

to

communicate

with

the

switch

module.

In

the

management

module

Web

interface,

in

Switch

Tasks

Management,

change

the

New

Static

IP

Configuration

values

to

match

the

ones

in

Current

IP

Configuration,

and

apply

the

configuration.

Light

path

diagnostics

LEDs

A

system-alarm

LED

on

the

system

LED

panel

is

lit

when

certain

system

errors

occur.

If

one

of

the

system-alarm

LEDs

on

your

BladeCenter

T

unit

is

lit,

use

the

following

table

to

help

determine

the

cause

of

the

error

and

the

action

you

should

take.

Note:

You

can

configure

the

major

and

critical

alarm

LEDs

to

be

either

amber

or

red

through

the

management

module.

Table

7.

Light

path

diagnostics

Lit

LED

Cause

Action

BladeCenter

T

system

LED

panel

Location

A

condition

has

occurred

in

the

BladeCenter

T

unit

that

has

caused

the

remote

system

management

to

identify

the

BladeCenter

T

unit

as

needing

attention.

Look

for

any

information

or

error

LEDs

on

the

system

LED

panels,

the

modules,

and

the

blade

servers

in

this

BladeCenter

T

unit,

and

follow

the

instructions

in

this

table

for

those

LEDs.

Minor

A

noncritical

event

has

occurred

that

should

be

looked

at,

such

as

the

wrong

I/O

module

inserted

in

a

bay,

or

power

needs

that

exceed

the

capacity

of

power

modules

currently

installed.

Check

the

error

log

for

the

messages.

Check

the

LEDs

on

the

BladeCenter

T

unit

and

the

blade

servers

to

isolate

the

component.

Major

A

major

system

error

has

occurred,

such

as

the

loss

of

one

of

two

mirrored

disks.

Note:

You

can

configure

the

major

error

LED

to

be

either

red

or

amber

through

the

management

module.

v

Check

the

error

log

for

messages.

v

Look

for

an

error

LED

on

the

modules

and

blade

servers

to

locate

the

component:

If

the

error

LED

is

on

a

module,

follow

the

instructions

for

the

module

in

this

table.

If

the

error

LED

is

on

a

blade

server,

see

the

documentation

that

comes

with

the

blade

server.

98

BladeCenter

T

Type

8720

and

8730:

Hardware

Maintenance

Manual

and

Troubleshooting

Guide