Blade server error messages, Blade, Server – IBM BladeCenter T Type 8720 User Manual

Page 111: Error, Messages

Advertising
background image

Note:

See

Chapter

7,

“Parts

listing,

BladeCenter

T

Type

8720

and

8730,”

on

page

107

to

determine

which

components

should

be

replaced

by

a

field

service

technician.

Message

Action

Power

supply

x

removed

Reinstall

power

supply

x.

System

over

recommended

voltage

for

+12V

1.

Reseat

the

management

module.

2.

Reseat

the

power

modules.

3.

Replace

the

power

modules.

4.

Replace

the

management

module.

System

over

recommended

voltage

for

+1.8V

1.

Reseat

the

management

module.

2.

Replace

the

management

module.

System

over

recommended

voltage

for

+2.5V

1.

Reseat

the

management

module.

2.

Replace

the

management

module.

System

over

recommended

voltage

for

+3.3V

1.

Reseat

the

management

module.

2.

Replace

the

management

module.

System

over

recommended

voltage

for

5V

1.

Reseat

the

management

module.

2.

Replace

the

management

module.

System

over

recommended

voltage

for

+5V

1.

Reseat

the

management

module.

2.

Replace

the

management

module.

System

under

recommended

voltage

for

+12V

1.

Reseat

the

management

module.

2.

Replace

the

management

module.

System

under

recommended

voltage

for

+1.8V

1.

Reseat

the

management

module.

2.

Replace

the

management

module.

System

under

recommended

voltage

for

+2.5V

1.

Reseat

the

management

module.

2.

Replace

the

management

module.

System

under

recommended

voltage

for

3.3V

1.

Reseat

the

management

module.

2.

Replace

the

management

module.

System

under

recommended

voltage

for

5V

1.

Reseat

the

management

module.

2.

Replace

the

management

module.

System

is

under

recommended

voltage

for

+5V

1.

Reseat

the

management

module.

2.

Replace

the

management

module.

System

running

nonredundant

power

Make

sure

that

power

modules

1

and

2

are

installed

and

operating

correctly.

If

blade

servers

are

installed

in

bay

5

or

higher,

make

sure

that

power

modules

3

and

4

are

installed

and

working

correctly.

Blade

server

error

messages

Note:

See

Chapter

7,

“Parts

listing,

BladeCenter

T

Type

8720

and

8730,”

on

page

107

to

determine

which

components

should

be

replaced

by

a

field

service

technician.

Message

Action

Blade

server

x

was

installed

Information

only.

Take

action

as

required.

Blade

server

x

was

removed

Information

only.

Take

action

as

required.

Chapter

6.

Symptom-to-FRU

index

101

Advertising
This manual is related to the following products: