IBM BladeCenter T Type 8720 User Manual

Page 24

Advertising
background image

Table

3.

Power

module

LEDs

(continued)

DC

IN

or

AC

IN

DC

OUT

!

(Error)

(amber)

Description

and

action

Off

Off

Off

or

On*

There

is

an

input

power

problem.

Possible

causes:

v

There

is

no

power

to

the

power

module.

Actions:

Make

sure

that:

1.

The

power

is

correctly

connected

to

the

unit.

2.

The

power

is

connected

to

220

v

ac

(8730)

or

–48

v

dc

(8720).

3.

The

power

source

functions

properly.

v

The

power

module

has

failed.

Action:

Replace

the

power

module.

If

the

problem

remains,

have

the

unit

serviced.

*Error

LED

will

operate

only

if

a

redundant

power

supply

is

installed.

On

On

On

There

is

a

fault

condition

in

the

power

supply.

Possible

causes:

v

Thermal

fault.

Action:

Replace

the

power

module.

v

12

v

over-voltage

power

condition

or

12

v

under-voltage

power

condition.

Actions:

Determine

the

cause

of

shutdown

using

diagnostics

and

replace

the

failed

component.

When

the

fault

has

ben

cleared,

reset

the

power

module.

Issue

a

power-module

reset

through

the

management

module.

Remove

the

power

module

from

the

unit

for

at

least

10

seconds.

14

BladeCenter

T

Type

8720

and

8730:

Hardware

Maintenance

Manual

and

Troubleshooting

Guide

Advertising