Power modules – IBM BladeCenter T Type 8720 User Manual

Page 23

Advertising
background image

Power

modules

AC in LED

DC out LED

DC in LED

Error LED

AC power module

DC power module

DC out LED

Error LED

Power

module

LEDs:

Each

power

module

has

three

LEDs

to

indicate

the

status

of

the

power

module.

v

AC

(or

DC)

in:

When

continuously

lit,

this

green

LED

indicates

that

the

input

power

source

is

working.

If

the

LED

is

not

lit,

it

indicates

that

the

input

power

source

is

not

present

or

is

incorrect.

v

DC

out:

When

continuously

lit,

this

green

LED

indicates

that

the

output

power

is

present.

If

the

LED

is

not

lit,

it

indicates

that

the

output

power

is

not

present.

v

!

(Error):

When

continuously

lit,

this

amber

LED

indicates

that

there

is

a

error

condition

within

the

power

module.

Table

3.

Power

module

LEDs

DC

IN

or

AC

IN

DC

OUT

!

(Error)

(amber)

Description

and

action

On

On

Off

The

power

module

is

on

and

operating

correctly.

On

Off

Off

or

On*

There

is

an

output

power

problem.

A

system

error

has

shut

down

the

power

module.

Actions:

Determine

the

cause

of

the

shutdown

using

the

diagnostics

and

replace

the

failed

component.

When

the

fault

has

been

cleared,

reset

the

power

module

in

one

of

the

following

ways:

v

Issue

a

power-module

reset

through

the

management

module.

v

Remove

the

power

module

from

the

unit

for

at

least

10

seconds.

If

the

problem

remains,

have

the

unit

serviced.

*Error

LED

will

operate

only

if

a

redundant

power

supply

is

installed.

Chapter

1.

General

information

13

Advertising