Temperature

error

messages

Note:

See

Chapter

7,

“Parts

listing,

BladeCenter

T

Type

8720

and

8730,”

on

page

107

to

determine

which

components

should

be

replaced

by

a

field

service

technician.

Message

Action

Power

supply

x

temperature

fault

1.

Make

sure

that

the

system

is

being

properly

cooled;

see

“System

reliability

considerations”

on

page

39.

2.

Replace

power

supply

x.

Power

supply

x

temperature

warning

1.

Make

sure

that

the

system

is

being

properly

cooled;

see

“System

reliability

considerations”

on

page

39.

2.

Replace

power

supply

x.

Switch

x

temperature

fault

1.

Make

sure

that

the

system

is

being

properly

cooled;

see

“System

reliability

considerations”

on

page

39.

2.

Replace

switch

x.

System

over

abbient

temperature

Make

sure

that

the

system

is

being

properly

cooled;

see

“System

reliability

considerations”

on

page

39.

Switch

x

temperature

fault

Make

sure

that

the

system

is

being

properly

cooled;

see

“System

reliability

considerations”

on

page

39.

Blower

error

messages

Note:

See

Chapter

7,

“Parts

listing,

BladeCenter

T

Type

8720

and

8730,”

on

page

107

to

determine

which

components

should

be

replaced

by

a

field

service

technician.

Message

Action

Blower

x

outside

recommended

speed

Replace

blower

x.

Blower

x

failure

Replace

blower

x.

Blower

x

fault

Replace

blower

x.

Power

error

messages

Note:

See

Chapter

7,

“Parts

listing,

BladeCenter

T

Type

8720

and

8730,”

on

page

107

to

determine

which

components

should

be

replaced

by

a

field

service

technician.

Message

Action

Power

module

3

or

4

is

required

to

power

blades

5

to

8

Make

sure

that

power

modules

3

and

4

are

installed

and

connected

to

power.

Power

supply

x

fault

Replace

power

module

x.

Power

supply

x

12V

over

voltage

fault

Replace

power

module

x.

Power

supply

x

12V

over

current

fault

1.

An

over

current

condition

is

typically

caused

by

an

external

load

fault.

Attempt

to

restart

the

faulted

power

module

by

removing

power

to

the

system

components

one

at

a

time

to

isolate

the

failing

component.

2.

Replace

power

module.

Power

supply

x

12V

under

voltage

fault

Replace

power

module

x.

Power

supply

x

12V

current

fault

Replace

power

module

x.

Power

supply

x

DC

good

fault

Replace

power

module

x.

100

BladeCenter

T