IBM BladeCenter T Type 8720 User Manual

Page 71

Advertising
background image

Table

5.

Hot-swap

I/O

module

types

by

location

for

redundancy

(continued)

Bays

I/O-module

function

Permissible

I/O

module

3

and

4

Network

connections

3

and

4

(for

all

I/O

expansion

options

on

blade

servers

in

the

BladeCenter

T

unit)

One

of

the

following

combinations.

v

Two

Ethernet

switch

modules

v

Two

Fibre

Channel

switch

modules

v

Two

pass-thru

modules

Important:

v

The

modules

used

must

support

the

network

interface

that

is

used

on

the

blade

server

I/O

expansion

options.

v

The

I/O

modules

in

bays

3

and

4

must

be

the

same

type.

Notes:

1.

The

enumeration

of

the

Ethernet

controllers

in

a

blade

server

is

operating-system

dependent.

You

can

verify

the

Ethernet

controller

designations

that

a

blade

server

uses

through

your

operating-system

settings.

2.

The

routing

of

an

Ethernet

controller

to

a

particular

I/O-module

bay

depends

on

the

type

of

blade

server.

You

can

verify

which

Ethernet

controller

is

routed

to

which

I/O-module

bay

by

using

the

following

test:

a.

Install

only

one

Ethernet

switch

module

or

pass-thru

module,

in

I/O-module

bay

1.

b.

Make

sure

that

the

ports

on

the

switch

module

or

pass-thru

module

are

enabled

(I/O

Module

Tasks

Management

Advanced

Management

in

the

management

module

Web-based

user

interface).

c.

Enable

only

one

of

the

Ethernet

controllers

on

the

blade

server.

Note

the

designation

that

the

blade

server

operating

system

has

for

the

controller.

d.

Ping

an

external

computer

on

the

network

that

is

connected

to

the

switch

module

or

pass-thru

module.

If

you

can

ping

the

external

computer,

the

Ethernet

controller

that

you

enabled

is

associated

with

the

I/O

module

in

I/O-module

bay

1.

The

other

Ethernet

controller

in

the

blade

server

is

associated

with

the

I/O

module

in

I/O-module

bay

2.

3.

If

you

have

installed

an

I/O

expansion

option

on

a

blade

server,

communications

from

the

option

are

routed

to

I/O-module

bays

3

and

4.

You

can

verify

which

controller

on

the

option

is

routed

to

which

I/O-module

bay

by

performing

the

test

in

note

2,

using

a

controller

on

the

I/O

expansion

option

and

a

compatible

switch

module

or

pass-thru

module

in

I/O-module

bay

3

or

4.

Use

the

instructions

in

this

section

to

remove

or

install

an

I/O

module

at

the

rear

of

the

BladeCenter

T

unit.

Chapter

4.

Setting

up

the

BladeCenter

T

hardware

61

Advertising
This manual is related to the following products: