IBM BladeCenter T Type 8720 User Manual

Page 109

Advertising
background image

Table

7.

Light

path

diagnostics

(continued)

Lit

LED

Cause

Action

Critical

error

A

critical

system

error

has

occurred,

such

as

nonredundancy

on

the

power

modules

or

a

system

error

in

a

blade.

Note:

You

can

configure

the

critical

error

LED

to

be

either

red

or

amber

through

the

management

module.

v

Check

the

error

log

for

messages.

v

Look

for

an

error

LED

on

the

modules

and

blade

servers

to

locate

the

component:

If

the

error

LED

is

on

a

module,

follow

the

instructions

for

the

module

in

this

table.

If

the

error

LED

is

on

a

blade

server,

see

the

documentation

that

comes

with

the

blade

server.

Management

module

System

error

A

critical

error

has

occurred

in

the

management

module.

v

If

your

BladeCenter

T

unit

has

only

one

management

module:

1.

Try

reseating

the

management

module.

2.

Restart

the

management

module.

If

the

problem

remains,

replace

the

management

module.

v

If

your

BladeCenter

T

unit

has

two

management

modules,

the

BladeCenter

T

unit

continues

to

function

using

the

redundant

module.

Replace

the

failed

management

module.

Active

Primary

management

module.

If

your

BladeCenter

T

has

two

management

modules,

the

Active

LED

indicates

which

is

the

primary

management

module.

Power

module

System

error

A

critical

error

has

occurred

in

the

power

module.

Reseat

the

power

module.

If

the

problem

remains,

replace

the

module.

If

your

BladeCenter

T

unit

has

a

redundant

module

for

this

power

module,

the

BladeCenter

T

unit

continues

to

function

using

the

redundant

module.

Blower

module

System

error

The

blower

has

failed

or

is

operating

too

slowly.

Reseat

the

blower

module.

If

the

problem

remains,

replace

the

blower

module

as

soon

as

possible,

to

regain

cooling

redundancy.

The

BladeCenter

T

unit

continues

to

function.

The

redundant

blower

module

provides

cooling

to

the

BladeCenter

T

unit

and

blade

servers.

I/O

module

System

error

A

critical

error

has

occurred

in

the

I/O

module.

Reseat

the

I/O

module.

If

the

problem

remains,

replace

the

module.

Chapter

6.

Symptom-to-FRU

index

99