Unit options, Unsigned 8, R/w/s – Intelligent Motion Systems MDrive DSP-402 User Manual

Page 29: Clock options, See table, Capture input, See entry desc

Advertising
background image

21

Part 2: DSP-402 Implementation

Object 2031h: Unit Options (Encoder Enable, Capture In/Trip Out)

Object Description

Index

2031

h

Name

Unit Options

Object Code

VAR

Data Type

Unsigned 8

Entry Description

Access

R/W/S

PDO Mapping

No

Range

0/1

Default

0

Note: Encoder functions only apply to the MDrive products. The MForce products do not have closed loop capability.

Bit

Position

0x80

0x40

0x20

0x10

0x08

0x04

0x02

0x01

0

Reserved Reserved

Reserved

Reserved

Encoder

Disabled

Capture In

Reserved

Reserved

1

Reserved Reserved

Reserved

Reserved

Encoder

Enabled

Trip Out

Reserved

Reserved

Default

0

0

0

0

0

0

0

0

Example

0

0

0

0

1

1

0

0

Object 2032h: Clock Options

Object Description

Index

2032

h

Name

Clock Options

Object Code

VAR

Data Type

Unsigned 8

Entry Description

Access

R/W/S

PDO Mapping

No

Range

See Table

Default

0

Bit

Position

0x80

0x40

0x20

0x10

0x08

0x04

0x02

0x01

0

n/a

n/a

n/a

n/a

n/a

n/a

n/a

n/a

1

Invert

Direction

Invert

Step

Reserved

Square

Out

Step Up/Dn

Reserved

Quadrature

Step/

Direction

Default

0

0

0

0

0

0

0

1

Example

0

0

0

0

1

0

0

Object 2033h: Capture Input

Object Description

Index

2033

h

Name

Capture Input

Object Code

VAR

Data Type

See Entry Desc.

Advertising