Following error window, Unsigned 32, Following error timeout – Intelligent Motion Systems MDrive DSP-402 User Manual

Page 58: Position window time, Unsigned 16, Mfg-specific

Advertising
background image

50

MDrivePlus CANopen R020507

Object 6065

h

— Following Error Window

This object shall indicate the conFigure d range of tolerated position values symmetrically to the position
demand value. If the position actual value is out of the following error window, a following error occurs. A
following error may occur when a drive is blocked, unreachable profile velocity occurs, or at wrong closed-
loop coefficients. The value shall be given in user defined position units. If the value of the following error
window is FFFF FFFFh, the following control shall be switched off.

Object Description

Index

6065

h

Name

Following Error Window

Object Code

VAR

Data Type

Unsigned 32

Entry Description

Access

r

PDO Mapping

n/a

Range

Unsigned 32

Default

n/a

Object 6066

h

— Following Error Timeout

This object shall indicate the conFigure d time for a following error condition, after that the bit 13 of the
statusword shall be set to 1. The reaction of the drive when a following error occurs is manufacturer-specific.
The value shall be given in milliseconds.

Object Description

Index

6066

h

Name

Following Error Timeout

Object Code

VAR

Data Type

Unsigned 32

Entry Description

Access

r

PDO Mapping

n/a

Range

Unsigned 32

Default

n/a

Object 6068

h

— Position Window Time

This object shall indicate the conFigure d time, during which the actual position within the position window
is measured. The value shall be given in milliseconds.

Object Description

Index

6068

h

Name

Position Window Time

Object Code

VAR

Data Type

Unsigned 16

Entry Description

Access

r

PDO Mapping

n/a

Range

Unsigned 16

Default

Mfg-Specific