Intelligent Motion Systems MDrive DSP-402 User Manual

Page 34

Advertising
background image

26

MDrivePlus CANopen R020507

State Machine Transitions

Transition

Number

From State

To State

Event/Action

0

Start

Not Ready To Switch

On

Event:

Reset.

Action:

The drive self-tests and/or self-initializes.

1

Not Ready To

Switch On

Switch On Disabled

Event:

The drive has self-tested and/or initialized

successfully.

Action:

Activate communication and process data

monitoring

2

Switch On Disabled Ready to Switch On

Event:

‘Shutdown’ command received from host.

Action:

None.

3

Ready to Switch On Switched On

Event:

‘Switch On’ command received from host.

Action:

The power section is switched on if it is not

already switched on.

4

Switched On

Operation Enable

Event:

‘Enable Operation’ command received from host.

Action:

The drive function is enabled.

5

Operation Enable

Switched On

Event:

‘Disable Operation’ command received from

host.

Action:

The drive operation will be disabled.

6

Switched On

Ready to Switch On

Event:

‘Shutdown’ command received from host.

Action:

The power section is switched off.

7

Ready to Switch On Switch On Disabled

Event:

‘Quick stop’ command received from host.

Action:

None

8

Operation Enable

Ready to Switch On

Event:

‘Shutdown’ command received from host.

Action:

The power section is switched off immediately,
and the motor is free to rotate if unbraked

9

Operation Enable

Switch On Disabled

Event:

‘Disable Voltage’ command received from host.

Action:

The power section is switched off immediately,
and the motor is free to rotate if unbraked

10

Switched On

Switch On Disabled

Event:

‘Disable Voltage’ or ‘Quick Stop’ command
received from host.

Action:

The power section is switched off immediately,
and the motor is free to rotate if unbraked

11

Operation Enable

Quick Stop Active

Event:

‘Quick Stop’ command received from host.

Action:

The Quick Stop function is executed.

12

Quick Stop Active

Switch On Disabled

Event:

‘Quick Stop’ is completed or ‘Disable Voltage’
command received from host. This transition
is possible, if the Quick-Stop-Option-Code is
different 5 (Stay in Quick-Stop)

Action:

The power section is switched off.

13

All States

Fault Reaction

Active

Event:

A fault has occured in the drive.

Action:

Execute appropriate fault reaction.

14

Fault Reaction

Active

Fault

Event:

Fault reaction is completed.

Action:

The drive function is disabled, the power section
may be switched off.

15

Fault

Switch On Disabled

Event:

‘Fault Reset’ command is recieved from the host.

Action:

A reset of the fault condition is carried out if no
fault exists currently on the drive. After leaving
the ‘Fault’ state the Bit ‘Fault Reset’ of the
controlword has to be cleared by
the host.

16

Quick Stop Active

Operation Enable

Event:

‘Enable Operation’ command received from

host. This transition is possible if the Quick-Stop-

Option-Code is 5,6,7 or 8.

Action:

The drive function is enabled

Table 4.2: State Machine Transitions