39

Part 2: DSP-402 Implementation

Object 6082

h

— End Velocity

The end velocity defines the velocity which the drive must have on reaching the target position. Normally, the drive
stops at the target position, i.e. the end_velocity = 0. The end velocity is given in the

same units

as profile velocity.

Object Description

Index

6082

h

Name

End Velocity

Object Code

VAR

Data Type

Integer 32

Entry Description

Access

rw

PDO Mapping

Possible

Range

Integer 32

Default

n/a

Object 6083

h

— Profile Acceleration

Profile Acceleration is given in steps/sec

2

Object Description

Index

6083

h

Name

Profile Acceleration

Object Code

VAR

Data Type

Integer 32

Entry Description

Access

rw

PDO Mapping

Possible

Range

Integer 32

Default

n/a

Object 6084

h

— Profile Deceleration

Profile Deceleration is given in steps/sec

2

Object Description

Index

6084

h

Name

Profile Deceleration

Object Code

VAR

Data Type

Integer 32

Entry Description

Access

rw

PDO Mapping

Possible

Range

Integer 32

Default

n/a