25

Part 2: DSP-402 Implementation

Section 4

Device Control

Device Control

The device control function block controls all the func-
tions of the MDrivePlus CANopen and is divided into to
sections:

1. Control of the State Machine

2. Operation Mode

Control and Status words

Controlword (Object Index 6040h) controls the state
and operation modes of the MDrivePlus CANopen.
Statusword (Object Index 6041h) returns the status of the
MDrivePlus CANopen.

State Machine

The State Machine describes the status and control sequence of the MDrivePlus CANopen and

specifies the Initialization sta-

tus, the Pre-Operational status, the Operational status, and the Stopped status. See Figure 1.2 for a diagrammatic representa-
tion of State machine states and state transitions.

State Machine States

State

Status Description

Not Ready to Switch On

Low Level Power Applied.

The drive is being initialized or is running a self test.

A brake, if present, is applied in this state.

The drive function is disabled.

Switch On Disabled

Drive Initialization is complete.

The drive parameters have been set up.

Drive parameters may be changed.

High Voltage may not be applied to the drive.

The drive function is disabled.

Ready To Switch On

High Voltage may be applied to the drive.

The drive parameters may be changed.

The drive function is disabled.

Switched On

High Voltage has been applied to the drive.

The Power Amplifier is ready.

The drive parameters may be changed.

The drive function is disabled.

Operation Enable

No faults have been detected.

The drive function is enabled and power is applied to the motor.

The drive parameters may be changed.

(This corresponds to normal operation of the drive.)

Quick Stop Active

The drive parameters may be changed.

The Quick Stop function is being executed.

The drive function is enabled and power is applied to the motor.

NOTE: If the ‘Quick-Stop-Option-Code’ is switched to 5 (Stay in Quick-Stop), the

MDrivePlus cannot exit the Quick-Stop-State, but you can transmit to ‘Operation

Enable’ with the command ‘Enable Operation’.

Fault Reaction Active

SUPPORT UNDER

DEVELOPMENT

The drive parameters may be changed.

A non-fatal fault has occurred in the drive.

The Quick Stop function is being executed.

The drive function is enabled and power is applied to the motor.

Fault

SUPPORT UNDER

DEVELOPMENT

The drive parameters may be changed.

A fault has occurred in the drive.

The drive function is disabled.

DEVICE CONTROL

State Machine

Controlword 6040

h

Profile Position
Profile Velocity

Modes of Operation

6060

h

Statusword

6041

h

Figure 4.1: Device Control

Table 4.1: State Machine States