Controlword, Unsigned16 – Intelligent Motion Systems MDrive DSP-402 User Manual

Page 36

Advertising
background image

28

MDrivePlus CANopen R020507

Object 6040

h

— Controlword

Ths controlword is a mandatory, unsigned 16 bit number containing bits for controlling the state and operating modes for the MDrivePlus

CANo-

pen

.

Object Description

Index

6040

h

Name

Controlword

Object Code

VAR

Data Type

Unsigned16

Entry Description

Access

r/w

PDO Mapping

n/a

Range

Unsigned16

Default

n/a

Data Description

MSB

15

11

10

9

8

LSB

7

6

4

3

2

1

0

Manufacturer

Specific

Reserved

Halt

Fault

Reset

Operation

Mode Specific

Enable

Operation

Quick

Stop

Enable

Voltage

Switch

On

O

O

O

M

O

M

M

M

M

O=Optional M= Mandatory

Device Control Command Bit Patterns (Bits 0-3 and 7)

Command

Bit of Controlword (6040h)

State

Transitions

Fault Reset

(Bit 7)

Enable

Operation

(Bit 3)

Quick Stop

(Bit 2)

Enable

Voltage

(Bit 1)

Switch On

(Bit 0)

Shutdown

0

X

1

1

0

2, 6, 8

Switch On

0

0

1

1

1

3

Switch On

0

1

1

1

1

3

Disable Voltage

0

X

X

0

X

7, 9, 10, 12

Quick Stop

0

X

0

1

X

7,10, 11

Disable Operation

0

0

1

1

1

5

Enable Operation

0

1

1

1

1

4, 16

Fault Reset

X

X

X

X

15

*The MDrivePlus CANopen executes the functionality of Switched On

** The MDrivePlus CANopen will do nothing

Table 4.3: MDrivePlus CANopen Device Control Commands (Bits Marked X are not relevant)

Device Operation Mode Bit Patterns (Bits 4-6 and 8)

Operation Mode

Controlword 6040h Bits 4-6, 8

Bit 8

Bit 6

Bit 5

Bit 4

Profile Position

Halt

Absolute/Relative

Change Set Immediately

New Setpoint

Profile Velocity

Halt

Reserved

Reserved

Reserved

Homing*

Halt

Homing Operation Start

Reserved

Reserved

*Homing Mode is currently under development for the MDrivePlus

CANopen

Table 4.4: MDrivePlus CANopen Operation Modes