Homing method, Integer 8, Possible – Intelligent Motion Systems MDrive DSP-402 User Manual

Page 51

Advertising
background image

43

Part 2: DSP-402 Implementation

Axis Direction

1

Index Pulse

Negative Limit Switch

Figure 7.3: Homing on the Negative Limit and Index Pulse

Homing Method (6098h)

The homing method object determines the method that will be used during homing.

Object Description

Index

6098

h

Name

Homing Method

Object Code

VAR

Data Type

± Integer 8

Entry Description

Access

rw

PDO Mapping

Possible

Range

± Integer 8

Default

0

Data Description

Value

Description

-128 — -1

Manufacturer Specific

0

No Homing Operation Required

1 — 35

Homing Methods 1 through 35 (See Functional Description)

36 — 128

Reserved

Functional Description of Homing Methods

Method 1: Homing on the Negative Limit Switch and Index Pulse

Using this method the initial direction of movement is leftward if the negative limit switch is inactive (here
shown as low). The home position is at the first index pulse to the right of the position where the negative limit
switch becomes inactive.

Advertising