Position demand value, Integer 32, Position actual value – Intelligent Motion Systems MDrive DSP-402 User Manual

Page 57

Advertising
background image

49

Part 2: DSP-402 Implementation

Section 8

Position Control Function

General Information

In this chapter, all parameters are described which are necessary for a closed loop position control. The control loop is fed
with the

position_demand_value as one of the outputs of the Trajectory Generator and with the output of the position detec-

tion unit (

position_actual_value) like a resolver or encoder as input parameters.

Object 6062

h

— Position Demand Value

This object shall provide the demanded position value. The value shall be given in motor steps.

Object Description

Index

6062

h

Name

Position Demand Value

Object Code

VAR

Data Type

Integer 32

Entry Description

Access

r

PDO Mapping

n/a

Range

Integer 32

Default

n/a

Object 6063

h

— Position Actual Value Internal

This object shall provide the actual value of the position measurement device, which shall be one of the two input values of
the closed-loop position control

Object Description

Index

6063

h

Name

Position Actual Value*

Object Code

VAR

Data Type

Integer 32

Entry Description

Access

r

PDO Mapping

n/a

Range

Integer 32

Default

n/a

Object 6064

h

— Position Actual Value

This object represents the actual value of the position measurement device microsteps.

Object Description

Index

6064

h

Name

Position Actual Value

Object Code

VAR

Data Type

Integer 32

Entry Description

Access

r

PDO Mapping

n/a

Range

Integer 32

Default

n/a

Advertising