Run current, Unsigned 8, R/w/s – Intelligent Motion Systems MDrive DSP-402 User Manual

Page 30: Hold current

Advertising
background image

22

MDrivePlus CANopen R020507

Entry Description

Sub-Index

Description

Category

Access

PDO

Mapping

Value Range

Default

Data Type

01h

Enable Capture

Position

R/W

Yes

0/1

02h

Enable Capture

Input Flag

R/W

No

0/1

03h

Capture Input

Filter

R/W

No

04h

Capture In

Position

R/W

No

Object 2204h: Run Current Percent

Object Description

Index

2204

h

Name

Run Current %

Object Code

VAR

Data Type

Unsigned 8

Entry Description

Access

R/W/S

PDO Mapping

No

Range

1 - 100

Default

25

Run Current % By Device

2204

h

MDrivePlus (All)

MForce MicroDrive

(Amps RMS)

MForce PowerDrive

(Amps RMS)

10

MDrive Range 0 To

100%

Actual Current Not

required as Motor is

appropriately sized

to the device.

0.3

0.5

20

0.6

1.0

30

0.9

1.5

40

1.2

2.0

50

1.5

2.5

60

1.8*

3.0

70

2.1

3.5

80

2.4

4.0

90

2.7

4.5

100

3.0

5.0

Shaded Area Reserved for Future Use

*HC=67 for maximum 2.0 Amp Hold Current

Object 2205h: Hold Current Percent

Object Description

Index

2205

h

Name

Hold Current %

Object Code

VAR

Data Type

Unsigned 8

Entry Description

Access

R/W/S

PDO Mapping

No

Range

0 - 100

Default

5

Advertising