46

MDrivePlus CANopen R020507

Home Switch

Negative Limit Switch

Index Pulse

14

14

13

12

11

11

11

12

12

13

13

14

Figure 7.8: Homing on the Home Switch and Index Pulse - Negative Initial Move

Methods 15 and 16: Reserved

These methods are reserved for future expansion of the homing mode.

Methods 17 to 30: Homing without an Index Pulse

These methods are similar to methods 1 to 14 except that the home position is not dependent on the index pulse
but only Dependent on the relevant home or limit switch transitions. For example methods 19 and 20 are similar
to methods 3 and 4 as shown in the following diagram.

Methods 31 and 32: Reserved

These methods are reserved for future expansion of the homing mode.

Home Switch

19

20

19

20

Figure 7.9: Homing without an Index Pulse

Advertising