Intelligent Motion Systems MDrive DSP-402 User Manual

Page 35

Advertising
background image

27

Part 2: DSP-402 Implementation

Power Disabled

Power Enabled

Fault

Start

Not Ready to Switch On

Fault Reaction Active

Fault

Switch On Disabled

Ready To Switch On

0

1

2

7

4

5

6

Switched On

Operation Enable

Quick Stop Active

9

3

8

16

11

10 12

14

13

15

Controlword 6040

h

Internal

Event

Statusword

6041

h

SUPPORT FOR FAULT

STATES UNDER

DEVELOPMENT

Figure 4.2: State Machine States/Transitions Block Diagram

Notes On State Transitions

Commands directing a change in state are processed completely and the new state achieved before additional state
change commands are processed.

Transitions 0 and 1 occur automatically at drive power-on or reset. All other state changes must be directed by the
host.

Drive function disabled indicates that no current is being supplied to the motor.

Drive function enabled indicates that current is available for the motor and profile position and profile velocity
reference values may be processed.