Position present point target, Integer 32, Position final point target – Intelligent Motion Systems MDrive DSP-402 User Manual

Page 31: R/w/s, Options setting, Unsigned 32

Advertising
background image

23

Part 2: DSP-402 Implementation

Hold Current % By Device

2205

h

MDrivePlus (All)

MForce MicroDrive

(Amps RMS)

MForce PowerDrive

(Amps RMS)

10

MDrive Range 0 To

100%

Actual Current Not

required as Motor is

appropriately sized

to the device.

0.3

0.5

20

0.6

1.0

30

0.9

1.5

40

1.2

2.0

50

1.5

2.5

60

1.8*

3.0

70

2.1

3.5

80

2.4

4.0

90

2.7

4.5

100

3.0

5.0

Shaded Area Reserved for Future Use

*HC=67 for maximum 2.0 Amp Hold Current

Object 2211h: Position Present Point Target

Object Description

Index

2211

h

Name

Position Present

Point Target

Object Code

VAR

Data Type

Integer 32

Entry Description

Access

R

PDO Mapping

No

Range

± 2

31

Default

0

Object 2212h: Position Final Point Target

Object Description

Index

2212

h

Name

Position Final Point

Target

Object Code

VAR

Data Type

Integer 32

Entry Description

Access

R/W/S

PDO Mapping

No

Range

± 2

31

Default

0

Object 5001h: Configuration

The following object is set at the factory, and is not user configurable.

Object Description

Index

5001

h

Name

Options Setting

Object Code

Data Type

Unsigned 32

Advertising