JVC VR-609 User Manual

Page 26

Advertising
background image

-- 26 --

VR-609

3.3.2 Setting values of TK-C676 or TK-C655

RS-485 Connector

Camera1
CONTROL Connector

VR-609

■ Connection of RS-485 Control signal cable

Camera2
CONTROL Connector

Camera9
CONTROL Connector

If there are OFF/ON of a camera power supply when not performing a home position
setup, camera angle will return to the factory setting.

Home position : the camera angle that is set to after power on.
(Without setting home position, the camera angle is set to factory setting after power
on.)

!

Terminal camera is set to ON.
Other cameras are set to OFF.

Switch 8

ON

Switch 5

Install ID value independently.

ID

ON

Switch 4

Value

Item

RX-

RX+

+

-

RX-

RX+

RX-

RX+

GND

When you install in a place with many noises,
please use a twisted-pair cable with a shield.
A shield cable should be connected to a GND
terminal.

D

C

D

C

D

C

・The functions can be used by this equipment are PAN/TILT/ZOOM/FOCUS/AUTO

FOCUS. (A setup of a home position, a preset position, etc. cannot be performed)
In addition, in order to perform a home position setup and a camera image setup in
advance, it is possible to use and set-up by remote controller of RM-P2580 grade.
Please read the Instructions of RM-P2580.

・About setting values of VR-609, please refer to 5.1.2 Camera details (P.42) and

5.1.3 Pan/Tilt Model Select (P.45).

Advertising