Vr-609 – JVC VR-609 User Manual

Page 29

Advertising
background image

-- 29 --

VR-609

3.4.2 External Product Connection of ALARM OUT and Application

Supports up to 4 separate alarms for motion control or alarms.
Possible to install output-events to each out terminal from the menu.

■ OUTPUT EVENTS

・Digital inputs to alarm 1~ 9, Disk Full, Video Loss, Power Off, Admin. PW Changed,

Motion Detect.

・When connecting to an external device, it is better to connect with the interface

circuit.

Alarm output terminals are 5V TTL output.

!

Connection Diagram

GND 1 2 3 4

Circuit Diagram

Alarm Output

47kΩ

5V

ALARM OUT

Terminal

Inside DVR Circuit