Analog Modules

5-73

S7-400, M7-400 Programmable Controllers Module Specifications
A5E00069467-07

Technical Specifications of the SM 431; AI 8

13 Bit

Programming package

Associated programming
package

As of STEP 7 V 2.0

Dimensions and Weight

Dimensions W

H

D

(in millimeters)

25

290

210

Weight

Approx. 500 g

Data for Specific Module

Number of inputs

•

For resistance-type sensor

8

4

Length of cable

•

Shielded

max. 200 m

Voltages, Currents, Potentials

Rated load voltage L+

Not required

Constant measured current for
resistance-type sensor

Typ. 1.67 mA

Isolation

•

Between channels and
backplane bus

•

Between the channels

Yes

No

Permitted potential difference

•

Between inputs and M

ANA

(U

CM

)

30 VAC

•

Between the inputs (E

CM

)

30 VAC

•

Between M

ANA

and

M

internal

(U

ISO

)

75 VDC / 60 VAC

Insulation tested with

•

Between bus and analog
section

•

Between bus and chassis
ground

•

Between analog section
and chassis ground

2120 VDC

500 VDC

2120 VDC

Current consumption

•

From the backplane bus

Max. 350 mA

Power dissipation of the
module

Typ. 1.8 W

Analog Value Generation

Measuring principle

Integrative

Integration time/conversion
time/resolution (per channel)

(Does not go into the
response time)

•

Parameters can be
assigned

Yes

•

Interference voltage
suppression f1 in Hz

60/50

•

Integration time in
milliseconds

16.7/20

•

Basic conversion time in
ms

23/25

•

Resolution including sign

13/13 Bit

Smoothing of the measured
values

Not possible

Basic execution time of the
module, in ms (all channels
enabled)

184/200

Suppression of Interference, Limits of Error

Interference voltage suppression for f = nx (f1

"

1%),

(f1 = interference frequency) n = 1, 2, ...

•

Common-mode
interference
(U

CM

< 30 V)

> 100 dB

•

Series-mode interference
(peak value of
interference < rated value
of input range)

> 40 dB

Crosstalk between the inputs

> 50 dB

Operational limit (in the entire temperature range, with
reference to the input range)

•

Voltage input

–

"

1 V

–

"

10 V

–

1 V to 5 V

"

1.0%

"

0.6%

"

0.7%

•

Current input

–

"

20 mA

–

4 mA to 20 mA

"

1.0%

"

1.0%

•

Resistance measurement
0 to 500

W;

four

Ć

conductor

measurement (in the range
of 600

W

)

"

1.25%

Basic error (operational limit at 25

°

5C, referred to input

range)

•

Voltage input

–

"

1 V

–

"

10 V

–

1 V to 5 V

"

0.7%

"

0.4%

"

0.5%

•

Current input

–

"

20 mA

–

4 mA to 20 mA

"

0.7%

"

0.7%

•

Resistance measurement
0 to 500

W;

four

Ć

conductor

measurement (in the range
of 600

W

)

"

0.8%

Temperature error with reference to the input range

•

In the resistance
measurement range

"

0.02% K

•

In all the other
measurement ranges

"

0.007% K

Linearity error (with reference
to the input range)

"

0.05% K

Repeat accuracy (in the steady
state at 25

°

C, referred to the

input range)

"

0.1%