6 emc compliance tests, 7 micromaster 411 – emc compliance – Siemens MICROMASTER 411 User Manual

Page 113

Advertising
background image

Issue 03/01

9 Electro-Magnetic Compatibility (EMC)

MICROMASTER 411 & COMBIMASTER 411 Operating Instructions

6SE6400-5CA00-0BP0

113

9.1.6

EMC Compliance Tests

Table 9-4

EMC Compliance Table

Model Remarks

Environment – General Industrial

6SE6411-6U***-**A1
1UA1**-**U**

Unfiltered units, all voltages and powers.

Environment – Filtered Industrial (All EU countries for year 2002)

6SE6411-6B***-**A1
1UA1**-**B**

Filtered units all voltages and powers.

Environment – Filtered for residential, commercial and light industry

6SE6411-6B***-**A1
1UA1**-**B**

Filtered units all voltages and powers.

* Denotes any value is allowed.

9.1.7

MICROMASTER 411 – EMC Compliance

The MICROMASTER 411 inverters will, when correctly installed and put to their
intended use, satisfy the requirements of the EEC Directive 89/336/EEC
concerning electromagnetic compatibility.

If the guidelines on installation to reduce the effects of electromagnetic interference
are followed, the devices are sutiable for installation in machines. According to the
machinery directive, these machines must be separately certified.

Table 9-5 below lists the measured results for emissions of an immunity to
interference for the MICROMASTER 411 inverters.

Table 9-5

MICROMASTER 411 Measured Results

Test Standard

Measurement

Test Value

Limit Value

RFI Emisions

Conducted via Mains Cable

150 kHz to 30 MHz

Unfiltered – not tested Class B

Emitted by the inverter

30 MHz to 1 GHz

All devices – Class A

Advertising