2 combimaster 411 dimensional detail, Combimaster 411- case size b – Siemens MICROMASTER 411 User Manual

Page 31

Advertising
background image

Issue 03/01

2 Installation

MICROMASTER 411 & COMBIMASTER 411 Operating Instructions

6SE6400-5CA00-0BP0

31

2.4.2

COMBIMASTER 411 Dimensional Detail

COMBIMASTER 411- Case Size B

Rear lip of Terminal Housing
taken as reference point for
Gland Measurements

Frame size 90S and 90L
have feet with 2 holes
each at the non-drive end.

222

36

128

168

27.6

135.6

154

Frame

Size

Motor Poles

T

L

T

W

T

H

M

F1

M

F2

M

F3

M

S1

M

S2

M

B1

71M

1LA7 070
1LA7 073

2 - 4

240

(9.4)

132

(5.2)

278.6

(11.0)

45

(1.8)

90

(3.5)

112

(4.4)

30

(1.2)

14

(0.6)

7

(0.3)

80M

1LA7 080

1LA7 083

2 - 4

274

(10.8)

309

(12.2)

150

(5.9)

296.6

(11.7)

50

(2.0)

100

(3.9)

125

(4.9)

40

(1.6)

19

(0.7)

9.5

(0.4)

90S

1LA7 090
1LA7 096

2 - 4

331

(13.0)

165

(6.5)

314.6

(12.4)

56

(2.2)

100

(3.9)

140

(5.5)

50

(2.0)

24

(0.9)

10

(0.4)

NOTES
1. All dimensions given in millimeters (and inches).
2. MF dimensions use Motor construction type IMB3.

Figure 2-8

COMBIMASTER 411 Case Size B Dimensional Detail