Warning – Lennox Hearth ELITE EDVCRPM-B User Manual

Page 14

Advertising
background image

14

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Schedule 40

Black Iron Pipe

Inside Diameter (Inches)

Schedule 40 Pipe

Length (feet)

Natural

Gas

Propane

Gas

0-10

1/2

3/8

10-40

1/2

1/2

40-100

1/2

1/2

100-150

3/4

1/2

150-200

3/4

1/2

Table 6

IMPORTANT: If propane is used, be aware that

if tank size is too small (i.e. under 100-lbs, if

this is the only gas appliance in the dwelling.

Ref. NPFA 58), there may be loss of pressure,

resulting in insufficient fuel delivery (which

can result in sooting, severe delayed ignition

or other malfunctions). Any damage resulting

from an improper installation, such as this, is

not covered under the limited warranty.

Step 3. PREPARING THE APPLIANCE

VENT COLLAR

Proper Sizing of Gas Line

Properly size and route the gas supply line

from the supply regulator to the area where the

appliance is to be installed per requirements

outlined in the National Fuel Gas Code, NFPA

54 - latest edition (USA) or CAN/CSA-B149.1

- latest edition (Canada).

Never use galvanized or plastic pipe. Refer to

Table 6 for proper sizing of the gas supply line,

if black iron pipe is being used. Gas lines must

be routed, constructed and made of materials

that are in strict accordance with local codes

and regulations. We recommend that a qualified

individual such as a plumber or gas fitter be

hired to correctly size and route the gas supply

line to the appliance.

Also see Figures 13 and 14.

Figure 21 - Route Gas Line

Step 2. ROUTING GAS LINE

Route a 1/2" (13 mm) gas line to the left side

of the appliance as shown in Figure 21. Gas

lines must be routed, constructed and made

of materials that are in strict accordance with

local codes and regulations. All appliances

are factory-equipped with a flexible gas line

connector and 1/2 inch shutoff valve. (See

Step 7 on Page 28).

Installing a gas supply line from the fuel supply to

the appliance involves numerous considerations

of materials, protection, sizing, locations, con-

trols, pressure, sediment, and more. Certainly no

one unfamiliar and unqualified should attempt

sizing or installing gas piping.

5-5/8"

(143 mm)

3-1/8"

(79 mm)

Notes:

• All appliances are factory-equipped with

a flexible gas line connector and 1/2 inch

shutoff valve.

• See Massachusetts Requirements on Page

4 for additional requirements for installations

in the state of Massachusetts in the USA.

• The gas supply line should Not be connected

to the appliance until Step 7 (Page 28).

• A pipe joint compound rated for gas should be

used on the threaded joints. Ensure propane

resistant compounds are used in propane

applications. Be very careful that the pipe

compound does not get inside the pipe.

• It is recommended to install a sediment

trap in the supply line as close as possible

to the appliance. Appliances using Propane

should have a sediment trap at the base of

the tank.

• Check with local building official for local

code requirements (i.e. are below grade

penetrations of the gas line allowed?, etc).

REMOVE VENT SEAL CAP

(From the vent that will be used only)

Top Vent Installations - See Figure 22

Side Vent Installations - See Figure 23

Preparing the Appliance Vent Collar

Each of the appliances' two vent collars are

sealed with a seal cap which must be removed

from the vent collar being used. Refer to Figure

22 for top vent installations and Figure 23 for

side vent installations and the following steps to

prepare the appropriate collar for use.

From the vent collar being used, remove the

two screws securing the vent seal cap. Twist

the cap counterclockwise. Pull it away from

the appliance and discard, along with the piece

of insulation.

WARNING

Failure to reinstall and securely

tighten vent seal cap screws

could result in leakage of flue

products into the living space.

Vent seal cap must remain

securely installed on unused

vent collar. Failure to do so

could result in leakage of flue

products into living space.

Advertising