NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

GEAR

CLAMPS

Adapter

(SV4.5RF)

Apply ONLY MIL-PAC BLACK HIGH

TEMPERATURE SEALANT (Catalog No.

10K81) to the outside surface of both

collars of the adapter (be especially

careful to fill the grooves of the outer

collar to be covered by the flexible

pipe) and slide flexible pipe over

inner and outer adapter collars.

NOTE: OUTER PIPE IS PULLED AWAY TO

SHOW THE DETAIL OF THE INNER PIPE

FLEX VENT

1-3/4 in. (44 mm)

Flexible Pipe and

Adapter Outer

Collar Overlap

1-3/4 in. (44 mm)

Flexible Pipe and

Adapter Inner

Collar Overlap

SECURING SCREW

(3 PLACES EQUALLY SPACED

JUST BELOW GEAR CLAMP)

Attach Adapter to Appliance

Collar, or Secure Vent Sections

SECURING SCREW

(3 PLACES EQUALLY SPACED

JUST BELOW GEAR CLAMP)

5" (127 mm)

Radius Minimum

Flexible Vent Section

E. Attach Flex Vent to Termination -

Secure Flex components can be purchased

separately and attached to bulk lengths of

Secure Flex flexible tubing cut to size at the job

site. Secure the flexible vent to the Secure Flex

terminations in the same manner (see Figure

49 ) as it was attached to the adapter.

See the appropriate sections and figures shown

throughout the venting section for their instal-

lation requirments.

Note: Secure Flex vent must be attached

to Secure Flex terminations only. DO NOT

substitute Secure Vent terminations or the

Secure Vent adapter for Secure Flex compo-

nents. The collars of Secure Flex terminations

and adapters have a different circumference

than that used with the Secure Vent pipe.

Additionally, Secure Flex components have

an extended length center tube for use in

attaching the flexible vent.

Figure 50

VERTICAL OR HORIZONTAL VENTING USING

SECuRE FlEx

KITS AND COMPONENTS

Secure Flex venting kits and components may

be used in any venting application where rigid

Secure Vent (SV4.5) direct vent components

can be used. All restrictions, clearances and

allowances that pertain to the rigid piping apply

to the flexible venting. Secure Flex kits may

not be modified; also, under no circumstances

may separate sections of flex pipe be joined

together. Secure Flex kits may be added to

the end of a vent run made up of rigid Secure

Vent (SV4.5) vent sections provided that doing

so does not violate any of the venting length,

height, routing, horizontal to vertical ratio re-

quirements or clearance considerations detailed

in this manual.

Secure Flex kits come with an included adapter

that can be fitted to the appliance collar or the

inclined channel end of the last Secure Vent

(SV4.5) vent section in a rigid system in the

exact same fashion as any other Secure Vent

section. Align the dimpled end of the adapter

over the previously installed section or appliance

collar, adjusting the radial alignment until the

four locking dimples of the adapter are aligned

with the inlets of the four incline channels of

the last vent section or collar. Push on the

adapter until it fully engages, then twist the

adapter clockwise running the dimples down

and along the incline channels until they seat

at the end of the channels.

Attach the flexible vent to the adapter as fol-

lows (see Figure 49):

A. Install the Inner Flex Pipe -

1. Install the small gear clamp loosely around

the inner flexible vent pipe, push it back out

of the way.

2. Apply a bead of Mill-Pac Black (700°F) high

temperature sealant - Catalog No. 10K81) to

the inner adapter collar, approximately 1/2 inch

from the end.

3. Pull and extend the inner flexible vent pipe.

4. Slide the inner flex pipe over the adapter

collar. Ensure the flexible vent pipe completely

engages the adapter collar to a distance of

1-3/4 inches from the end, and that it is free

from damage or tears.

5. Slide the gear clamp down and tighten it

fully to secure the flexible vent to the adapter

inner collar approximately 3/4 inch from the

end of the flex.

6. Install three screws 120 degrees apart

through the flexible vent pipe and into the adapter

collar just below the gear clamp to provide ad-

ditional security to the connection.

B. Install the Outer Flex Pipe -

1. Install the large gear clamp loosely around

the outer flexible vent pipe, push it back out

of the way.

2. Apply a bead of Mill-Pac Black (700°F) high

temperature sealant - Catalog No. 10K81) to

the outer adapter collar; to the grooves of the

collar which extend approximately 1 inch from

the end and to the flat surface, approximately

1-3/8 inches from the end.

3. Pull and extend the outer flexible vent pipe.

4. Slide the outer flex pipe over the adapter

collar. Ensure the flexible vent pipe completely

engages the adapter collar to a distance of 1³⁄₄

inches from the end, and that it is free from

damage or tears.

5. Slide the gear clamp down and tighten it

fully to secure the flexible vent to the adapter

outer collar approximately 3/4 inch from the

end of the flex.

6. Install three screws 120 degrees apart

through the flexible vent pipe and into the adapter

collar just below the gear clamp to provide ad-

ditional security to the connection.

C. Route Flex Vent -

Ensure that the flex vent is properly routed to

provide the required clearance. Do Not allow

the flexible vent to bend in a radius tighter than

5" (127 mm). Refer to Figure 50. Support

horizontal sections of flex with metal straps at

2 foot (0.61 m) intervals.

D. Install Firestop/Spacers at ceilings and walls -

When Secure Flex penetrates a wall or ceiling,

a firestop/spacer is required: use the SF4.5 VF

firestop/spacer for ceilings and the SF4.5 HF

firestop/spacer for walls.