NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

When first lighting the appliance, it will take a

few minutes for the line to purge itself of air.

Once purging is complete, the pilot and burner

will light and operate as indicated in the instruc-

tion manual.

Subsequent lighting of the appliance will not

require such purging. Inspect the pilot flame (re-

move logs, if necessary, handling carefully).

Millivolt Appliance Checkout

The pilot flame should be steady, not lifting

or floating. Flame should be blue in color with

traces of orange at the outer edge.

The top 3/8" (10 mm) at the pilot generator

(thermopile) and the top 1/8" minimum (tip)

of the quick drop out thermocouple should be

engulfed in the pilot flame.

The flame should project 1" (25 mm) beyond the

hood at all three ports (see Figure 57). Replace

logs if removed for pilot inspection.

To light the burner; turn “ON” the remote wall

switch and rotate the gas valve control knob

counterclockwise to the “ON” position (“ON”

will be at the top side of the valve).

Figure 56

Piezo Ignitor

Gas Valve

Modesty Panel

Control

Compartment

Access panel

ON/OFF

Switch

Hinge Pin

Step 9. INSTALL VERMICULITE, GLOW-

ING EMBERS AND LOGS

NOTE: Turn off all electricity to the appliance

before you install vermiculite, embers and logs.

DO NOT attempt to install the logs until the ap-

pliance installation has been completed, the gas

line connected and tested for leaks and the initial

burner operation has been checked out.

MILLIVOLT
Thermocouple

Hood Igniter Rod

3/8" Min

(9 mm)

Thermopile

Pilot

Nozzels

Electronic Appliance Checkout

To light the burner, turn ‘ON’ the unit mounted

On/Off switch or the optional remote wall switch.

Ensure the igniter lights the pilot. The pilot

flame should engulf the flame rod as shown

in Figure 58.

Figure 57

Figure 55 -

GAS CONNECTION

Gas

Stub

1/2" x 3/8" Flare

Shut-Off Valve

3/8" Flex Tubing

3/8" NPT x 3/8"

Flare Fitting

3/8" Nipple

3/8" Union

3/8" Close Nipple

3/8" Shut-Off Valve

1/2" x 3/8"

Reducer

Gas

Valve

Optional Gas Flex-Line Connector

ELECTRONIC

Proper Flame

Adjustment

Pilot

Nozzle

3/8 To 1/2 Inch

(9 mm to 13 mm)

Ground

Electrode

Flame Rod

Hot Surface

Igniter

Figure 58