Caution, Warning, Never use an open flame to check for leaks – Lennox Hearth ELITE EDVCRPM-B User Manual

Page 28

Advertising
background image

28

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Note: Supply wires may be alternatively con-

nected to the outlet using the screw terminals,

however the black supply wire must be wired to

a terminal that is opposite (across the outlet) the

point where the white supply wire is connected.

Bipolar

Terminal

Screw

Ground Wire

Connection

White

(supply)

Black

(supply)

Figure 52

Step 6.

WIRING - OPTIONAL FORCED AIR

BLOWER KIT

FBK-100, FBK-200 and FBK-250 Kits

(See Figure 54 on page 29 for wiring) -

An electrical receptacle is provided for the

installation of the FBK-100, FBK-200 and FBK-

250 forced air blower kits. Electrical power

must be connected to this receptacle in order

to operate these blowers. Install the blower

kits according to the installation instructions

provided with the kits.

Outlet Receptacle

Junction Box

Field-provided Metal Junction Box

Cover Plate With Screw

View Of Left

Bottom Corner Of Unit

Receptacle, Junction Box

and Cover Plate Installation

Fireplace

Side

Junction Box

knock-out (2

places each side)

Valve Access Side

latching magnet

not shown

Press snap

bushing into the

knock-out for

control switch

wires.

Step 7. CONNECTING GAS LINE

Make gas line connections. All codes require a

shut-off valve mounted in the supply line. Figure

55 illustrates two methods for connecting the

gas supply. The flex-line method is acceptable

in the U.S., however, Canadian requirements

vary depending on locality. Installation must

be in compliance with local codes. A sediment

trap is recommended in the gas piping within

the home to prevent moisture and debris in the

line from damaging the valve.

These appliances are equipped with a gas flex

line for use (where permitted) in connecting the

unit to the gas line. A gas flex line is provided

to aid in attaching the direct vent appliance to

the gas supply. The gas flex line can only be

used where local codes permit. The flex line

is rated for both natural and propane gas. A

manual shut off valve is also provided with

the flex line.

The gas control valve is located in the lower

control compartment.

To access the valve open the lower control

compartment door (see Figure 56 ) by pushing

in the right top corner of the door. (The door

is hinged at the bottom.) Remove the bottom

compartment door by sliding the hinge pin,

located at the door’s left side, to the right until

it disengages from the left corner post hole.

Pull the door diagonally to the left, away from

the fireplace.

The lower control compartment door on the

side opposite the valve lifts on and off.

The millivolt control valve has a 3/8"

(10 mm) NPT thread inlet port. The electronic

control valve has a 1/2" (13 mm) NPT thread

inlet port and is fitted with a 1/2" x 3/8" (13 mm x

10 mm) NPT fitting.

Secure all joints tightly using appropriate

tools and sealing compounds (ensure propane

resistant compounds are used in propane

applications).

All codes require a shut-off valve mounted

in the supply line. The orientation of the

shut-off valve should face the front. Figure

55 illustrates two methods for connecting the

gas supply. A sediment Trap is recommended

to prevent moisture and debris in the gas line

for damaging the valve.

Figure 53

CAUTION

Remove the carton support from

the control compartment before

operating the appliance.

WARNING

Never use an open flame to

check for leaks.

TEST ALL CONNECTIONS FOR GAS LEAKS

(FACTORY AND FIELD):