WARNINGS

Air shutter adjustment should

only be performed by a quali-

fied professional service tech-

nician.

Ensure front glass panel are

in place and sealed during

adjustment.

CAUTIONS

Soot will be produced if the

air shutter is closed too much.

Any damage due to sooting,

resulting from improperly

setting the air shutter, is not

covered under the warranty.

The air shutter door and

nearby appliance surfaces

are hot. Exercise caution to

avoid injury while adjusting

flame appearance.

1. Refer to Figure 64 for proper flame appearance. To adjust the flame, rotate the adjustment rod toward the back or toward the front of the

fireplace (rod located in the lower control area). Position the air shutter to the factory setting as shown in the table in Figure 65.

2. Light appliance (follow lighting procedure on lighting label in control compartment or see the Care and Operation Manual).

3. Allow the burner to operate for at least 15 minutes while observing the flame continuously to ensure that the proper flame appearance has been

achieved. If the following conditions are present, adjust accordingly.

• If flame appears weak or sooty, adjust the air shutter, incrementally, to a more open position until the proper flame appearance is achieved.

• If flame remains blue, adjust the air shutter, incrementally, to a more closed position until the proper flame appearance is achieved.

4. Leave the control knob (off/pilot/on) in the ON position and the burner OFF/ON switch OFF (and remote switches, if applicable).

5. When satisfied that the burner flame appearance is normal, re-install the lower control compartment door then proceed to finish the installation.

Figure 64 -

Burner Flame Appearance