NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

d. Locate the two (2) latches at the top of the

control compartment. To disengage the two

latches from the bottom vee-flange of the glass

enclosure panel, reach for the handles located

towards the back of the latches and pull the

handles down toward the front of the unit. See

Figure 63 on page 34.

e. Swing the bottom of the door out and raise

it slightly to lift the top flange of the door frame

away from the appliance.

Step 2. Carefully remove the log set. Exercise

care as not to break the log set.

Step 3. Referring to Figure 67, remove the

burner.

FRONT OF FIREPLACE

PAN BURNER

VENTURI TUBE ARM

AIR SHUTTER

ADJUSTMENT LEVER

FIREBOX SUBFLOOR

Figure 67

Millivolt Appliances

Step 4. Refer to Figure 68 and the instruc-

tions provided with the kit. Using a Torx T20,

remove and discard the three pressure regulator

mounting screws. Remove the pressure regu-

lator, spring, poppet, diaphragm and bushing.

Discard all removed components. Ensure

the rubber gasket installed on the back of the

replacement pressure regulator is properly

positioned and install the new pressure regula-

tor using the new screws supplied with the kit.

Tighten screws to 25 In. lb. torque.

Spring

Adjusting

Screw

Slotted

Cap

PSI

OFF

I

ON

CONTROL

IGNITE

Manifold

Pressure

Test Port

Inlet Pressure Test Port

Pressure

Regulator

Remove

These

Components

Pilot

Orifice

Retaining

Clip

Ignitor

Assembly

Pilot

Assembly

Pilot

Orifice

Flare Nut

All Models

Step 8. (Refer to Figure 67 )

A. Remove the orifice from the manifold and

replace it with the one provided in the kit.

The following table shows the orifice sizes

for natural and propane models. Figure 72

illustrates the orifice. Always check and verify

correct orifice size.

When reinstalling the ignitor assembly, use

extreme care to prevent damage and break-

age. Do not apply any leverage to the ignitor

assembly while restoring the retainer clip to

its original position.

Note: If the ignitor is damaged, a replacement kit

is available, order Catalog No. 87L54.

Electronic Appliances

Step 7. Honeywell Electronic Valves - See

Figure 70 and the instructions provided with

the kit. Remove the slotted cap screw, o-ring,

pressure-regulating adjusting screw and spring.

Retain all parts for possible later use. Install

new components from the kit. Black cap and

red spring for propane gas units. Silver cap

and stainless steel spring for natural gas units.

Before installing the cap, attach manometer to

the manifold side pressure test fitting and adjust

screw until pressure reads 3.5 inches water col-

umn (0.87 kPa) for natural gas, and 10.0 inches

water column (2.49 kPa) for propane gas.

See Figure 71 and replace the pilot orifice as fol-

lows: Remove the ignitor assembly retainer clip,

and carefully remove the ignitor assembly.

Exercise extreme care to prevent damage to

or breakage of the ignitor assembly.

Remove the screw securing the pilot assembly

to its mounting bracket. Back off the flare nut

at the end of the pilot gas line to free the pilot

assembly from the gas line. Remove the pilot

orifice and replace it with the one provided with

the conversion kit. Reinstall the pilot assembly

by reversing the steps detailed here.

Step 5. Attach manometer to the manifold side

pressure test fitting and verify manifold pres-

sure reads 3.5 inches water column (0.87 kPa)

for natural gas, and 10.0 inches water column

(2.49 kPa) for propane gas.

Step 6. Refer to Figure 69 and remove the

pilot hood assembly to access the hexed pilot

orifice. Remove and replace the orifice with the

one provided with the kit.