NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Step 5. FIELD WIRING

TP-TH

TP

TH

APPLIANCE- MOUNTED

ON/OFF SWITCH

(OPTIONAL)

BK/W(1)

BK/W(1)

WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)

THERMOSTAT (OPTIONAL)

JUNCTION BOX

BLACK

W

GR

120 V AC

WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)

BK

R

WIRING DIAGRAM MILLIVOLT GAS VALVES

THERMOPILE

GAS VALVE

FAN

(OPTIONAL)

Figure 51

Refer to Section A for millivolt appliances and

Section B for electronic appliances. The gas

valve is set in place and pre-wired at the factory

on both models.

A. Millivolt Wiring (See Figure 51)

Install Optional Control Switch (OFF/ON wall

switch, wall thermostat or remote control

receiver). Install snap bushing (provided in

Electrical Outlet Kit) into control switch knock-

out in side panel (see Figures 17 through 20 and

53). Wire the optional control switch within the

millivolt control circuit (as shown in Figure 51)

using the 15 feet of 2 conductor wire supplied

(route wires through the snap bushing to the

optional control switch). Mount the optional

control switch or wall thermostat in a convenient

location on a wall near the fireplace.

CAUTION

Ground supply lead must be con-

nected to the wire attached to the

green ground screw located on the

outlet box. See

Figures 52 & 53

. Fail-

ure to do so will result in a potential

safety hazard. The appliance must be

electrically grounded in accordance

with local codes or, in the absence of

local codes, the National Electrical

Code, ANSI/NFPA 70-latest edition.

(In Canada, the current CSA C22-1

Canadian Electrical Code).

CAUTION: Label all wires prior to disconnec-

tion when servicing controls. Wiring errors can

cause improper and dangerous operation.

ATTENTION: Au moment de l'entretien des

commandes, étiquetez tous les fils avant de

les débrancher. Des erreurs de cáblage peu-

vent entraîner un fonctionnement inadéquat

et dangereux.

Verify proper operation after servicing.

S'assurer que l'appareil fonctionne adé-

quatement une fois l'entretien terminé.

CAUTION

Do not connect optinal control switch

to 120VAC power supply.

2. Install the junction box and receptacle outlet

to the left of the valve in the front (for optional

blower kit). See junction box and receptacle

outlet as explained in steps 1-11 for (B) Elec-

tronic Wiring (on this page).

B. Electronic Wiring (See Figure 54)

Note: The electronic appliance must be con-

nected to the main 120 VAC power supply.

1. Locate the Electrical Outlet Kit provided

(packaged in firebox - contents: junction box, 2

screws, receptacle outlet, OFF/ON rocker switch

-for millivolt units only, and a snap bushing).

Note: The junction box can be installed in any of

the 4 outside corners of the control compartment

(outlet installed in front left corner is shown in

Figure 53 ). If an optional blower is to be installed

place the junction box to the left of the valve in

the front corner.

2. Route a 3-wire, 120 VAC, 60 Hz, 1 ph power

supply to the location on appliance where junc-

tion box is to be installed.

3. Open the control compartment access

panel.

4. Wire and install the outlet receptacle to junc-

tion box, then install into the chosen corner of

the control compartment as shown in Figures

51, 52 and 54.

5. After the receptacle/junction box wiring is

complete, install the field-provided metal junc-

tion box cover plate (see Figure 53).

6. Install the snap bushing (provided in kit)

into the selected cabinet knockout opening in

side cabinets (see Figures 17 through 20 and

53). The snap bushing provides protection for

the wires (see note below) passing through

side cabinet going to an optional burner control

switch Wire in the burner control switch to the

low voltage circuit as shown in Figure 54.

Note: The supplied 15 feet of 2 conductor wire

has one end of each conductor connected to the

gas valve circuit and the other end of each con-

ductor placed loose on top of the appliance.

Important Note: The gas valve OFF/ON switch

is shown in Figure 56 on Page 30. It is integral

with the gas valve and should be set to the

ON position.

WARNING

Electronic models of these appli-

ances are equipped with a three-

prong (grounding) plug utilized

in connecting the electronic

components to the junction box

in the lower compartment. This

grounding plug provides protec-

tion against shock hazard and

should be plugged directly into

the properly grounded three-

prong receptacle. DO NOT cut

or remove the grounding prong

from the plug.