Warning – Lennox Hearth ELITE EDVCRPM-B User Manual

Page 23

Advertising
background image

23

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Venting Components Required for Various Exterior Wall

Thicknesses, when using Typical Termination Kits

Vent Components Required Exterior Wall Thickness - inches (mm)
Termination Kit Only

6 to 9-1/4 (152 to 235)

Termination Kit and 6 In. Vent

Section (SV4.5L6)

10-3/4 to 14 (273 to 356)

Termination Kit and 12 in.

Vent Section (SV4.5L12)

16-3/4 to 20 (426 to 508)

Termination Kit and Tele-

scopic Section (SV4.5L12)

11-3/4 to 20 (299 to 508)

Table 8

Note: See Figure 42 showing wall thickness range

when using SV4.5HT-2 termination kit.

HORIZONTAL VENT FIGURES/TABLES

Note: Two 45 degree elbows may be used in place of one 90 degree

elbow. The same rise to run ratios, as shown in the venting figures for

90 elbows, must be followed if 45 degree elbows are used.

Note: It is very important that the horizontal/inclined run be maintained

in a straight (no dips) and recommended to be in a slightly elevated

plane, in a direction away from the fireplace of 1/4" rise per foot (20

mm per meter) which is ideal, though rise per foot run ratios that are

smaller are acceptable all the way down to at or near level.

Note: SV4.5VF (Secure Vent), SF4.5VF (Secure Flex) firestop/spacer must

be used anytime vent pipe passes through a combustible floor or ceiling.

SV4.5HF (Secure Vent), SF4.5HF (Secure Flex) firestop/spacer must be

used anytime vent pipe passes through a combustible wall.

Note: Secure Vent components (rigid vent pipe and terminal) are shown

in the figures; Secure Flex components (flexible vent pipe and terminal)

may also be used.

u

Wall Firestop / Spacer

(SV4.5HF)

H = 28 in. (711 mm)

Maximum

7 in. (711 mm)

21 in. (533 mm)

Maximum

u

When using

Secure Flex, use

Firestop / Spacer

SF4.5HF

See Table 8 as an aid in venting component selection for a particular range

of exterior wall thicknesses.

Square

termination

(SV4.5HT-2)

shown

Figure 43

- Side Vent, NO ELBOWS

H

V

v

Wall Firestop/Spacer

(SV4.5HF)

Table F

H Maximum

V Minimum

feet

(meter)

feet

(meter)

3

(0.914)

Elbow Only

5

(1.524)

1

(0.305)

10

(3.048)

2

(0.610)

15

(4.572)

3

(0.914)

20

(6.096)

4

(1.219)

V + H = 40 feet (12.2 m) Max.

H = 20 ft. (6.096 m) Max.

Example: If 20 feet of (H) horizontal vent run is needed, then 4 feet

minimum of (V) vertical vent will be required.

This table shows a 1(V) to 5(H) ratio. For every 1 foot of vertical, you are

allowed 5 feet of (H) horizontal run up to a maximum (H) horizontal run

of 20 feet.

u

When using Secure Flex, use Firestop / Spacer SF4.5VF

v

When using Secure Flex, use Firestop / Spacer SF4.5HF

Figure 44

-

Top Vent, ONE 90 DEGREE ELBOW

See Table 8 as an aid in venting component

selection for a particular range of exterior wall

thicknesses.

Square termination (SV4.5HT-2)

shown.

WARNING

Under no circumstances, may separate sections of

concentric flexible vent pipe be joined together.