NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Framing Dimensions for Roof

Pitch

C

D

0/12

10-1/2 in.

10-1/2 in.

(267 mm) (267 mm)

6/12

10-1/2 in.

12 in.

(267 mm) (305 mm)

12/12

10-1/2 in.

17-3/4 in.

(267 mm) (451 mm)

Figure 31

Figure 32

Figure 34

Figure 33

If the vent system extends more than 5' (1.5

m) above the roof flashing, stabilizers may be

necessary. Additional screws may be used at

section joints for added stability. Guide wires

may be attached to the joint for additional sup-

port on multiple joint configurations.

G. Continue installation of horizontal/inclined

sections - Continue with the installation of the

straight vent sections in horizontal/inclined run

as described in Step C. Install support straps

every 5' (1.52 m) along horizontal/inclined vent

runs using conventional plumber’s tape. It is

very important that the horizontal/inclined

run be maintained in a straight (no dips) and

slightly elevated plane in a direction away

from the fireplace 1/4" per foot (20 mm per

meter) of horizontal vent. Use a carpenter’s

level to measure from a constant surface and

adjust the support straps as necessary.

It is important to maintain the required clear-

ances to combustibles: 1" (25 mm) at all sides

for all vertical runs; and 3" (76 mm) at the top,

1" (25 mm) at sides, and 1" (25 mm) at the

bottom for all horizontal/inclined runs.

F. Change vent direction to horizontal/inclined

run - At transition from or to a horizontal/in-

clined run, install the SV4.5E45 and SV4.5E90

elbows in the same manner as the straight vent

sections. The elbows feature a twist section to

allow them to be routed about the center axis

of their initial collar section to align with the

required direction of the next vent run element.

Twist elbow sections in a clockwise direction

only so as to avoid the possiblity of unlocking

any of the previously connected vent sections.

See Figure 30.

E. Support the vertical vent run sections -

Note - Proper venting support is very important.

The weight of the vent must not be supported

by the fireplace in any degree.

Support the vertical portion of the venting

system every 8 feet (2.4m) above the fireplace

vent outlet. One method of support is by utiliz-

ing field provided support straps (conventional

plumber's tape). Secure the plumber's tape to

the framing members with nails or screws. Loop

the tape around the vent, securing the ends of

the tape to the framing. If desired, sheet metal

screws #6 x 1/2" length may be used to secure

the support straps to the vent pipe. Refer to

Figure 29.

Figure 30

SV4.5E90

(90

°

Elbow)

8-1/8"

(206 mm)

Swivel Joint

(360

°

swivel)

4-13/16"

(122 mm)

SV4.5E45

(45

°

Elbow)

Swivel Joint

(360

°

swivel)

C

D

Storm

Collar

K. Install the vertical termination - The final

step involves installation of the SV4.5CGV-1

Vertical Termination. Extend the vent sections

to the height as shown in the "Vertical vent ter-

mination section" on page 6. The SV4.5CGV-1

Vertical Termination (Figure 34 ) installs in the

exact same fashion as any other Secure Vent

section. Align the termination over the end of

the previously installed section, adjusting the

radial alignment until the four locking dimples

of the termination are aligned with the inlets of

the four incline channels of the last vent section.

Push the termination down until it fully engages,

then twist the termination clockwise running the

dimples down and along the incline channels

until they seat at the end of the channels.

I. Install the roof flashing - Extend the vent

sections through the roof structure. Install the

roof flashing over the vent section and posi-

tion such that the vent column rises vertically

(use carpenters level) (Figure 32 ). Nail along

perimeter to secure flashing or adjust roofing

to overlap the flashing edges at top and sides

only and trim where necessary. Seal the top

and both sides of the flashing with waterproof

caulking.

J. Install the storm collar - Install the storm

collar, supplied with the flashing, over the vent/

flashing joint. See Figure 33. Loosen the storm

collar screw. Slide collar down until it meets

the top of the flashing. Tighten the adjusting

screw. Apply non-combustible caulking or

mastic around the circumference of the joint

to provide a water tight seal.

H. Frame roof opening - Identify location for

vent at the roof. Cut and/or frame opening per

Roof Framing Chart and Figure 31.