NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Securing Screws

(OUTSIDE of

Appli

ance)

Insulation

Top Vent

Vent Seal Cap

Firebox Top

Cabinet Top

CROSS SECTION

SIDE VENT SEAL CAP REMOVAL

(SIDE VENT INSTALLATIONS ONLY)

Insulation

Vent Seal Cap

Securing Screws

Side Vent

Cabinet Back

CROSS SECTION

(INSIDE of Appliance)

(OUTSIDE of

Appli

ance)

(INSIDE of

Appli

ance)

Figure 22 -

Figure 23 -

TOP VENT SEAL CAP REMOVAL

(TOP VENT INSTALLATIONS ONLY)

Step 4. INSTALL THE VENT SYSTEM

General Information

These instructions should be used as a guideline and do not supersede

local codes in any way. Install venting according to local codes, these

instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the

USA or the current standards of CAN/CSA-B149.1 in Canada.

Ensure clearances are in accordance with local installation codes and

the requirements of the gas supplier.

Dégagement conforme aux codes d'installation locaux et aux exigences

du foumisseunde gaz.

Use only approved venting components. See Approved Vent

Components on Page 2.

These fireplaces must be vented directly to the outside.

The vent system may not service multiple appliances, and must never

be connected to a flue serving a solid fuel burning appliance. The vent

pipe is tested to be run inside an enclosed wall (such as a chase). There

is no requirement for inspection openings in the enclosing wall at any of

the joints in the vent pipe.

Installation of Vent Restrictor

A vent restrictor may be needed with this appliance. The restrictor is

installed in the appliance top flue outlet as shown in Figure 24, either

before adding vent, from above, or after installation of vent from below,

within the firebox. The restrictor is self securing through a positive

friction fit.

Determine the venting for the appliance. If the vent run will include at

least 8 feet of vertical rise, then install the restrictor in the appliance

collar before connecting any vent (Refer to Figure 24 ). Place the

restrictor inside the appliance vent collar and press in place.

Note: The restrictor is included within the firebox.

Select Venting System - Horizontal or Vertical

With the appliance secured in framing, determine vent routing and identify

the exterior termination location. The following sections describe vertical

(roof) and horizontal (exterior wall) vent applications. Refer to the section

relating to your installation. A list of approved venting components are

shown on Pages 38 and 39.

Figure 24

Appliance

Vent Outlet

Restrictor

Inner

Fireplace

Collar

VENT RESTRICTOR INSTALLATION

A vent restrictor may be needed when vertically terminating the vent

system above the roof (when using the appliance top vent), install a vent

restrictor in the top vent of the fireplace outlet.

If needed, install the restrictor as shown, either from inside or outside the

unit, in the inner fireplace collar.

Top Shown - Rear Similar

Advertising