Removing the power supply module, Removing the power supply module -17 – Philips 862478 User Manual

Page 141

Advertising
background image

Disassembly Procedures

Disassembly

7-17

Removing the
Power Supply

Module

Step

Action

1

Use the needle-nose pliers to unplug the three connectors.

2

Remove the two screws that connect the power supply to the rear panel.

3

Remove the screws on the side and bottom of the rear panel.

4

Cut the tie wrap that holds the battery cables together.

5

Use a 5/16 nut driver to unfasten the power supply from the rear panel.

6

Pull the power supply module away from the rear panel.

Connector #1

Connectors #2 & 3

Power Supply Board

Battery Cables

Communications Module

Advertising
This manual is related to the following products: