Error installing usb tape drive, Recovery, Replacement of cpu host card – Nortel Networks NN10265-111 User Manual

Page 83: Replacement of task processor, R to, Error installing

Advertising
background image

MCS 5100 RTP Media Portal Basics

83

Copyright © Nortel Networks Limited 2006

Mount volume 2
then enter volume name (default: /dev/rmt/0cn)

Mount volume 3
then enter volume name (default: /dev/rmt/0cn)

Read error while restoring
./me/loads/pool9/Files/B/UAS06.zip.bLfCbwYvd5YvveYt
continue? [y n] n
Verify volume and initialize maps
Media read error: I/O error
rest*: No such file or directory
12:49:35 Failed to Restore /IMS/imssipdb directory,
aborting restore process
Logs are written to
/export/home/sysadmin/bkup_restore/mcp_recover.pl.
log.2004_03_24.12:49:35

Error installing USB tape drive
If there is an error installing a USB tape drive, reboot the server and log
in as root. Then type the command shutdown -y -g0 -i6 and press
Enter
.

Recovery

The following procedures include instructions to replace the CPU host
card and task processor.

Replacement of CPU host card

If a CPV5370 fails, calls in progress stay up but call control is lost. Calls
cannot be controlled again, nor can any new calls be set up on that
Portal until the CPV5370 has been replaced and the new CPV5370 is
in service.

If a CPU host card fails, replace the bad card with a new one. Follow
steps in

BIOS configuration of the CPV5370 Host Card on page 90

to

make the appropriate BIOS changes to the new card.

Replacement of task processor

If the RTP Media Portal MCPN765 fails, all calls set up on that blade are
lost at the time of the failure and cannot be recovered. Replace the bad
card, and perform the following initialization procedures. This
procedure requires a special cable to configure the BIOS of the card.

From the terminal device

1

Set up the MCPN765 Card. For more information, refer to

Setting up the MCPN765 I/O Card on page 104

.

Advertising