Nortel Networks VT100 User Manual

Page 34

Advertising
background image

Template files 2-21

Meridian IVR VT100 Gateway Development Guide Product release 2.0/I

If you enter “0,0” and a hyphen for the row,column and field-name entries,
the field I/O specified is executed at the current cursor location.

To locate field-names on the screen for reading, the offset of the upper left
corner of the screen is 1,1 and the lower, right corner is 24,80.

field-name

This entry identifies the field being accessed on the terminal

screen. If the field-descriptor is 0,0 (i.e., for an exact match), the field-name
must uniquely match text on the screen or must be a hyphen to indicate that
the field is at the current cursor position. When entering the field name, keep
in mind that the TRS process right-justifies all field names and removes all
extra white space. If the transaction fails, this field identifies the current
screen so the reset-action template can be executed.

If you enter “0,0” and a hyphen for the row, column and field-name entries,
the field I/O specified is executed at the current cursor location.

To specify a specific location on the screen that does not have an associated
field-name, use a hyphen, “-”, for the field-name entry. If you do, you must
specify a location, such as 24,8 for the location of the action specified by the
field-I/O entry.

field-I/O

This entry indicates the action to be taken on the field. Table 2-1

explains the valid entries for this field.