CHAPTER 8 USB FUNCTION

User’s Manual U12978EJ3V0UD

126

Notes 1. Be sure to follow the exact instruction sequence when the Resume signal (“K” state) is output.

SET1

REMWUP.3

; (PULLDM

← 1)

CLR1

REMWUP.2

; (PULLDP

← 0)

MOV

A, #00000111B ; (A

← 00000111B)

SET1

REMWUP.1

; (PULLEN

← 1)

SET1

REMWUP.0

; (WAKEUP

← 1), “J” state output

MOV

REMWUP, A

; (REMWUP

← A), “K” state output

2. Be sure to follow the exact instruction sequence to append EOP when terminating Resume output.

CLR1

REMWUP.0

; (WAKEUP

← 0)

, Resume output end

CLR1

REMWUP.1

; (PULLEN

← 0)

CLR1

REMWUP.2

; (PULLDP

← 0)

SET1

REMWUP.3

; (PULLDM

← 1)

Figure 8-22. Configuration of Remote Wakeup Control

TXEN

Note

WAKEUP (REMWUP.0)

PULLDP (REMWUP.2)

Transmit data (+ side)

Transmit data (- side)

PULLDM (REMWUP.3)

PULLEN (REMWUP.1)

<Analog part>

<Function part>

D+ pin (USBDP)

D- pin (USBDM)

SEP, SEM disable signal

TX MASTER EN

Note

Note Because this signal is used internally, confirmation by software is not possible.

“J” state generation

“J” state generation