CHAPTER 16 ELECTRICAL SPECIFICATIONS

User’s Manual U12978EJ3V0UD

215

(b) 3-wire serial I/O mode (T

A

=

−−−−40 to +85°°°°C, V

DD

= 4.0 to 5.5 V)

(i) SCK10 ...Internal clock output (when f

X

= 6.0 MHz)

Parameter

Symbol

Conditions

MIN.

TYP.

MAX.

Unit

When TPS100

Note 1

= 0

667

667

667

ns

SCK10 cycle time

t

KCY1

When TPS100

Note 1

= 1

1,333

1,333

1,333

ns

When TPS100

Note 1

= 0

283

333

ns

SCK10 high-/low-level width

t

KH1

,

t

KL1

When TPS100

Note 1

= 1

617

667

ns

SI10 setup time

t

SIK1

To SCK10

150

ns

When TPS100

Note 1

= 0

333

ns

SI10 hold time

t

KSI1

From SCK10

When TPS100

Note 1

= 1

667

ns

SO10 output delay

t

KSO1

From SCK10

↓, CL = 100 pF

Note 2

0

200

ns

Notes 1. Bit 4 of serial operation mode register 10 (CSIM10)

2. CL is the capacitance of the SO output line.

(ii) SCK10 ...External clock output

Parameter

Symbol

Conditions

MIN.

TYP.

MAX.

Unit

SCK10 cycle time

t

KCY2

667

ns

SCK10 high-/low-level width

t

KH2

,

t

KL2

283

ns

SI10 setup time

t

SIK2

100

ns

SI10 hold time

t

KSI2

333

ns

SO10 output delay

t

KSO2

From SCK10

↓, CL = 100 pF

Note

0

250

ns

Note CL is the capacitance of the SO output line.